Wednesday, October 6, 2010
Surface Impact Loads for Buried pipeline
1. Maximum impact load
The impact loads described in this section are those resulting from large weights falling from
significant heights. In this case, the use of an impact factor F , as applied in Section 4, is not
sufficient to estimate the effect of the impact load on the buried pipe. The surface impact load
due to the weight W of a fallen object
2.Penetration and PPV
For impact near the pipe location, the increased pressure transmitted to the pipe can be evaluated
as described in Section 4 where Pmax is the applied surface load. This evaluation considers the
ovality, through-wall bending, side wall crushing, and ring buckling. In addition, the burial depth
should be sufficient to guard against ground penetration by falling objects.
Example problem see the link
http://www.4shared.com/document/pfUVB8pb/Example_problem_for_Maximum_Im.html